30

Insulation Material

 

Target Scope


Insulation material (limited to those that use extruded polystyrene foam, rigid polyurethane foam, glass fiber (including glass wool; the same applies hereinafter), slag wool or rock wool), except the following:

1) vacuum insulation material,

2) insulation material using rigid polyurethane foam that have no face material,

3) air-blast type insulation material using rigid polyurethane foam,

4) blow-in type insulation material using glass fiber, slag wool or rock wool, or

5) insulation material using glass fiber that have a density of 24 kg/m3 or more.

 

Heat Loss Prevention Performance


Heat loss prevention performance shall be thermal conductivity (W/(m・K)) found by the measurement method stipulated in JIS A 9521 (2017).

 

Categories & Target Standard Values


In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting heat loss prevention performance with dimension shipped shall not be above the target standard value.


Category Category name [Target standard value]
Standard heat loss prevention performance
Base material Type
Extruded polystyrene foam Extruded polystyrene foam insulation material 0.03232
Glass fiber Glass wool insulation material 0.04156
Slag wool or rock wool Rock wool insulation material 0.03781
Rigid polyurethane foam Type 2 Rigid urethane foam insulation material – type 2 0.02216
Type 3 Rigid urethane foam insulation material – type 3 0.02289
Remarks:
  1. “Type 2” refers to rigid urethane foam insulation material - type 2 stipulated in JIS A 9521 (2017).
  2. “Type 3 “refers to rigid urethane foam insulation material - type 3 stipulated in JIS A 9521 (2017).

 

Target Fiscal Year


[Extruded polystyrene foam, glass fiber, slag wool or rock wool-based insulation material]

●FY2022 and each subsequent fiscal year


[Rigid polyurethane foam-based insulation material]

●FY2026 and each subsequent fiscal year

 

Performance Improvement


●For extruded polystyrene foam insulation material, heat loss prevention performance is expected to be improved by 6.19% compared with the FY2012 level in the target fiscal year (FY2022).

●For glass wool insulation material, heat loss prevention performance is expected to be improved by 6.04% compared with the FY2012 level in the target fiscal year (FY2022).

●For rock wool insulation material, heat loss prevention performance is expected to be improved by 0.50% compared with the FY2012 level in the target fiscal year (FY2022).

●For rigid urethane foam insulation material, heat loss prevention performance of those falling into Type 2 category is expected to be improved by 3.40% and heat loss prevention performance of those falling into Type 3 category is expected to be improved by 4.23% compared with the FY2016 level in the target fiscal year (FY2026).

 

Display Items


●Product name or type

●Category name

●Heat loss prevention performance

●Name of manufacturer, etc.

 

Display Location


Display items shall be presented at locations where they can be readily noticed on product bodies including packaging and also in catalogs showing performance indications or documents provided by the manufacturer for product selection.

 

Requirement for Recommendations and Orders


Manufacturers, producers or importers whose annual manufacturing volume or importing volume (limited to shipment to the domestic market) is 180,000 m2 or more may be subject to recommendations and orders.