26
Electric Water Heaters
Target Scope
Electric water heaters (limited to those that utilize heat pump units using carbon dioxide as a refrigerant), except the following:
1) ones for heating, or
2) ones for business use.
Energy Consumption Efficiency
Energy consumption efficiency shall be the ratio of the heating amount (MJ) per unit time imparted to the circulating water to the amount of power consumption (kWh) when a heat pump is running. For those with a bathtub water reheating function, it is referred to as the annual water heating and reheating efficiency. For those without a bathtub water reheating function, it is referred to as the annual water heating efficiency. The measurement method is in accordance with the method stipulated in JIS C 9220.
Categories & Target Standard Values
①FY2017 and each subsequent fiscal year (until FY2024)
In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting energy consumption efficiency with shipment volume shall not be below the target standard value.
Category | [Target standard value] Standard energy consumption efficiency | |||||
---|---|---|---|---|---|---|
Category name | Presumed household | Storage capacity | Specifications | Reheating function | Number of storage tanks | |
1 | Standard | Less than 240 liters | Other than cold region specifications | Y | One | 2.8 |
2 | Mltiple | 2.4 | ||||
3 | N | One | 3.0 | |||
4 | Mltiple | 2.6 | ||||
5 | Cold region specifications | Y | One | 2.3 | ||
6 | Mltiple | 2.0 | ||||
7 | N | One | 2.6 | |||
8 | Mltiple | 2.3 | ||||
9 | 240 liters or more Less than 320 liters | Other than cold region specifications | Y | One | 2.8 | |
10 | Mltiple | 2.8 | ||||
11 | N | One | 3.2 | |||
12 | Mltiple | 2.8 | ||||
13 | Cold region specifications | Y | One | 2.3 | ||
14 | Mltiple | 2.0 | ||||
15 | N | One | 2.7 | |||
16 | Mltiple | 2.3 | ||||
17 | 320 liters or more Less than 550 liters | Other than cold region specifications | Y | One | 3.3 | |
18 | Mltiple | 2.8 | ||||
19 | N | One | 3.2 | |||
20 | Mltiple | 2.8 | ||||
21 | Cold region specifications | Y | One | 2.7 | ||
22 | Mltiple | 2.3 | ||||
23 | N | One | 2.7 | |||
24 | Mltiple | 2.3 | ||||
25 | 550 liters or more | Other than cold region specifications | Y | One | 2.9 | |
26 | Mltiple | 2.5 | ||||
27 | N | One | 2.9 | |||
28 | Mltiple | 2.5 | ||||
29 | Cold region specifications | Y | One | 2.4 | ||
30 | Mltiple | 2.1 | ||||
31 | N | One | 2.5 | |||
32 | Mltiple | 2.2 | ||||
33 | Small family | ― | Other than cold region specifications | Y | ― | 2.4 |
34 | N | 2.8 | ||||
35 | Cold region specificationst | Y | 2.0 | |||
36 | N | 2.4 |
Remarks: |
|
②FY2025 and each subsequent fiscal year
In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting energy consumption efficiency with shipment volume shall not be below the target standard value.
Category | [Target Standard value] Standard energy consumption efficiency |
||||
---|---|---|---|---|---|
Category Name |
Presumed Household |
Number of storage tanks | Storage Capacity |
Specifications | |
A | Small Family |
― | ― | Other than cold region specifications | 3.0 |
B | Cold region specifications | 2.7 | |||
C | Standard | One | Less than 320 liters | Other than cold region specifications | 3.1 |
D | Cold region specifications | 2.7 | |||
E | 320 liters or more Less than 550 liters | Other than cold region specifications | 3.5 | ||
F | Cold region specifications | 2.9 | |||
G | 550 litters or more | Other than cold region specifications | 3.2 | ||
H | Cold region specifications | 2.7 | |||
I | Mltiple | ― | Other than cold region specifications | 3.0 | |
J | Cold region specifications | 2.7 |
Remarks: |
|
Target Fiscal Year
FY2017 and each subsequent fiscal year (until FY2024)
FY2025 and each subsequent fiscal year
Energy Efficiency Improvement
Energy consumption efficiency is expected to be improved by about 5% compared with the FY2017 level in the target fiscal year (FY2025).
Display Items
●Product name and type
●Category name
●Energy consumption efficiency
●Name of manufacturer, etc.
Display Location
Display items shall be presented at locations where they can be readily noticed in catalogs showing performance indications and in instruction manuals.
Requirement for Recommendations and Orders
Manufacturers or importers whose annual manufacturing volume or importing volume (limited to shipment to the domestic market) is 500 units or more may be subject to recommendations and orders.