15
Oil Water Heaters
Target Scope
Oil water heaters, except the following:
1) ones which are not the objects of JIS S 3021(2017) , 3024(2017), or JIS S 3027(2017)(without high pressure type of small oil water heaters and high pressure type of bath tub oil water heaters that are stipulated in JIS S 2091(2013)),
2) ones for business use,
3) ones for hot water supply, which are storage type for heating and are not instantaneous type for heating, or
4) ones for heaters, which are storage type for heating and are not instantaneous type for heating.
Energy Consumption Efficiency
①FY2006 and each subsequent fiscal year (until FY 2024)
Energy consumption efficiency shall be heat efficiency (%) measured as stipulated in JIS S 3031(2009).
②FY2025 and each subsequent fiscal year
[Hot water supply]
●Energy consumption efficiency shall be heat efficiency (%) measured as stipulated in JIS S 2075 (2011)
[Heater]
●Energy consumption efficiency shall be heat efficiency (%) measured as stipulated in JIS S 3031 (2009)
Categories & Target Standard Values
①FY2006 and each subsequent fiscal year (until FY 2024)
In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting energy consumption efficiency with shipment volume shall not be below the target standard value.
Category | [Target standard value] Standard energy consumption efficiency | |||
---|---|---|---|---|
Purpose | Heating type | Air supply and exhaust type or control method | Category name | |
For hot water supply | Instantaneous type | ― | A | 86.0 |
Storage type with rapid heating system | ― | B | 87.0 | |
Storage types other than rapid heating system | ― | C | 85.0 | |
For heaters | Instantaneous type | Unvented type | D | 85.3 |
Vented type | E | 79.4 | ||
Direct vent type | F | 82.1 | ||
Storage type with rapid heating system | On/off control | G | 87.0 | |
Other than on/off control | H | 82.0 | ||
Storage types other than rapid heating system | ― | I | 84.0 | |
For baths | Water heaters with a center flue heat exchanger | ― | J | 75.0 |
Water heaters without a center flue heat exchanger | ― | K | 61.0 |
Remarks: |
|
②FY2025 and each subsequent fiscal year
In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting energy consumption efficiency with shipment volume shall not be below the target standard value.
Category | [Target standard value] Standard energy consumption efficiency |
|||
---|---|---|---|---|
Category name | Purpose | Heating type | ||
Ⅰ | For hot water supply | Without bath use | Instantaneous type | 89.68×βⅠi |
Ⅱ | Storage type | 76.88 | ||
Ⅲ | With bath use | Instantaneous type | 90.01×βⅢi | |
Ⅳ | Storage type | 76.07 | ||
Ⅴ | For heaters | Storage type | 87.06×βⅤi |
Structure type | βⅠi |
|
---|---|---|
Structure name |
Structure | |
Ⅰ-1 | Pressure-spray-type | 0.9585 |
Ⅰ-2 | Other | 1.0000 |
Structure type | βⅢi |
|
---|---|---|
Structure name |
Structure | |
Ⅲ-1 | Pressure-spray-type | 0.9492 |
Ⅲ-2 | Other | 1.0000 |
Structure type | βⅤi |
|
---|---|---|
Structure name |
Structure | |
V-1 | On/off control(limited to conventional type) | 1.0051 |
V-2 | Other | 1.0000 |
【Judgment criteria exceptions】
The manufacturers of appliances are required to keep the harmonic mean of the energy consumption efficiency of appliances shipped for each fiscal year starting from the targeted fiscal year, weighted with shipment volume by category, at the same level or higher than the harmonic mean of the standard energy consumption efficiency weighted with shipment volume by category. Also as an exception, evaluation through average thermal efficiency by company is adopted.
Target Fiscal Year
- FY2006 and each subsequent fiscal year (until FY2024)
- FY2025 and each subsequent fiscal year
Energy Efficiency Improvement
Energy consumption efficiency was improved by about 7.1 in the target fiscal year (FY2025).
Display Items
●Product name and type
●Category name
●Structure name(limited to cases of category Ⅰ, category Ⅲ or category Ⅴ)
●Energy consumption efficiency
●Name of manufacturer, etc.
Display Location
Display items shall be presented at locations where they can be readily noticed in catalogs showing performance indications and on product bodies.
Requirement for Recommendations and Orders
Manufacturers or importers whose annual manufacturing volume or importing volume (limited to shipment to the domestic market) is 600 units or more may be subject to recommendations and orders.