12

Space Heaters

 

Target Scope


Space heaters using gas or oil for fuel, except the following:

1) ones of unvented type,

2) ones using gases other than either those of City Gas 13A group or liquefied petroleum gas for fuel,

3) vented gas space heaters,

4) vented oil space heaters with maximum fuel consumption of over 4.0L/h, or

5) direct vent type oil space heaters with maximum fuel consumption of over 2.75L/h.

 

Energy Consumption Efficiency


Energy consumption efficiency shall be heat efficiency (%) measured in the manner stipulated in JIS S 2122 or JIS S 3031.

 

Categories & Target Standard Values


In the target fiscal year and each subsequent fiscal year, for each category, the weighted average value obtained by weighting energy consumption efficiency with shipment volume shall not be below the target standard value*1.

*1: For Category E of oil space heaters, the weighted average value obtained by weighting standard energy consumption obtained from the standard energy consumption calculation formula with shipment volume.

●Gas space heaters

Category[Target standard value]
Standard energy consumption efficiency
Direct vent type82.0

●Oil space heaters

Category[Target standard value]
Standard energy consumption efficiency or calculation formula
Air supply and exhaust typeHeat transfer typeCategory name
Direct vent typeNatural convection typeA83.5
Forced convection typeB86.0
Vented typeRadiating typeC69.0
Other than radiating types with maximum fuel consumption of 1.5 liters per hour or lessD67.0
Other than radiating types with maximum fuel consumption of more than 1.5 liters per hourEE=-3.0L+71.5
Remarks: E and L shall express the following numeric values.
E: Standard energy consumption efficiency (unit: percent)
L: Maximum fuel consumtion (unite: litters per hours)

 

Target Fiscal Year


FY2006 and each subsequent fiscal year

 

Energy Efficiency Improvement


●For gas space heaters whose target fiscal year was FY2006, energy consumption efficiency was improved by about 1.8% compared with the FY2000 level in the target fiscal year (FY2006).

●For oil space heaters whose target fiscal year was FY2006, energy consumption efficiency was improved by about 5.3% compared with the FY2000 level in the target fiscal year (FY2006).

 

Display Items


●Product name or type

●Category (limited to oil space heaters)

●Maximum fuel consumption (limited to non-radiation type vented oil space heaters whose maximum fuel consumption is over 1.5L/h)

●Energy consumption efficiency

●Name of manufacturer, etc.

 

Display Location


Display items shall be presented at locations where they can be readily noticed in catalogs showing performance indications and on product bodies.

 

Requirement for Recommendations and Orders


Manufacturers or importers whose annual manufacturing volume or importing volume (limited to shipment to the domestic market) is 300 units or more may be subject to recommendations and orders.